Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 24 of 24 items found.

  • Wafer Probe Loadboards/PIB

    Dynamic Test Solutions

    DTS has a full line of standard PIBs for all major tester platforms. Custom PIB designs can accommodate any test head, prober and manipulator configuration, including probe card changers, overhead direct dock setups and cable interfaces. DTS wafer test loadboards are compatible with a variety of pogo pin interface towers. All PIBs are constructed with impedance control, precision matched line lengths, full power and ground planes and both analog and digital resources to provide high quality signal integrity directly to the device.

  • Auto Reclose and Sync Check

    Mors Smitt Group

    Operating records for overhead power lines reveal that most faults are of a transient nature (e.g. lightning induced) & that service interruptions may be minimized by use of automatic reclosing of circuit breakers. An automatic reclosure of the circuit breaker, after the fault clears, provides improved service continuity & system stability. The 1B230 Series Reclose Relay provides for single or double shot automatic reclosing of circuit breakers, following interruption of supply due to a fault in the system.

  • Transformer & Capacitor Testers

    Greenlee Tools

    *Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing

  • Transformer/Capacitor Test Sets

    Greenlee Tools

    *Quick and easy check for opens or shorts on transformers or capacitors before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers as well as capacitors and capacitor banks*Tests the primary and secondary sides of de-energized transformers and capacitors without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer or capacitor*Automatic self-test featureMagnet holds the tester in place while testing

  • EZ-Glider Inverted Telescoping Torque Arms

    Mountz Inc.

    The EZ-Glider inverted telescoping torque arms securely keep electric or pneumatic torque tools in perpendicular or a level alignment to help prevent side loading or cross threading occurring during the assembly process. Crafted with lightweight durable carbon fiber the torque arm collapses like a telescope. The torque arms are ideal for assembly lines like automotive, aerospace and appliance where space is a premium and operator safety is mandatory. The ergonomic design of the EZ-Glider torque arms reduces RMI (repetitive motion injury) and CTS (carpal tunnel syndrome). The effortless handling of the torque arm provides comfortable tool operation and increased production. The flexible telescoping arms provide manufacturers the ability to mount the arms to a wall, workbench, a standard rail system, aluminum extrusion or existing overhead system. The torque arms are maintenance free.

  • Wiring Diagnostic System

    TRACER 1.0 - Tweddle Group

    TRACER creates vehicle- and fault-specific diagrams on the fly. It can diagnose the probable cause of failure in a network of wiring harnesses and modules and lets technicians choose a CAD view of the wiring layout to find the precise failure location (down to a specific pin), so they can correct the issue efficiently. Tracer saves labor costs, overhead costs and helps avoid collateral damage. TRACER streamlines ELT and dealership repair. It's helpful for all vehicles, particularly new models, where technicians lack the familiarity to assess and resolve electrical issues in a timely manner. TRACER also makes aberrant anomalies a thing of the past—when a vehicle rolls down the line with a never-before-seen combination of electrical failures, resolution becomes a matter of routine. TRACER dramatically reduces effort and increases efficiency.

  • Small Form Factor Mission Computers

    Curtiss-Wright Defense Solutions

    Our commercial off-the-shelf (COTS), small form factor (SFF) mission computer systems feature modular, expandable designs that pair powerful graphics and data processing capabilities with ultra-reliable mechanical robustness. The Parvus DuraCOR line of field-tested, MIL-STD qualified mission processors has been proven in the harshest C5ISR applications, performing reliably under thermal, shock, and vibration extremes. We provide application engineering services to extend base system computing functionality for these SFF systems, adding in application-specific I/O and communications cards typically with minimal NRE fees or delivery schedule impact. With pre-integrated, pre-qualified systems tailored by the factory, Parvus DuraCOR customers dramatically reduce scheduling risk and program management overhead, while maximizing use of open architecture COTS technologies. Available in ultra-small, small and standard form factors, we have solutions to meet you SWaP requirements.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

Get Help